基于EKF的永磁同步电机启动速度状态监测与补偿策略

Research on an EKF-based Speed-State Monitoring and Compensation Strategy for Startup of Permanent Magnet Synchronous Motors

  • 摘要: 针对永磁同步电机无位置传感器启动时,初始位置估计误差过大易导致堵转甚至启动失败的问题,本文提出一种基于扩展卡尔曼滤波(EKF)的启动状态监测与补偿策略。首先,基于EKF对电流、转速及转子位置进行估计,建立考虑误差角的电磁转矩与机械运动模型;通过转矩平衡关系划分六类启动状态,揭示了零速非期望平衡的形成机理。进而,在EKF的q轴电流预测方程中引入与q轴控制电压成比例的补偿项,以打破该非期望平衡,保障电机正常启动。仿真结果表明:在80°,160°和240°初始误差角下,未加补偿时系统均启动失败,而引入补偿后均成功启动;启动过程的转速上升时间最长为0.25 s,稳态转速误差及最终位置误差角绝对值分别被控制在4.9 rad/s 和9.2°以内;在变速工况以及突加/突卸负载扰动下,系统同样表现出良好的鲁棒性,稳态转速误差绝对值最大仅为 4.36 rad/s。与现有q轴电流补偿策略相比,所提策略进一步降低了稳态转速误差。该策略将状态估计与启动异常抑制相结合,在免去额外硬件传感器的同时,显著提升了较大初始位置误差下的启动可靠性,为工业传动系统的状态监测提供了新思路。

     

    Abstract: Abstract: To address the problems of locked-rotor and startup failure caused by excessive initial position estimation errors during the sensorless startup of permanent magnet synchronous motors (PMSMs), a startup state monitoring and compensation strategy based on the extended Kalman filter (EKF) was proposed. First, the EKF was employed to estimate the currents, speed, and rotor position. An electromagnetic torque model and a mechanical motion model considering the position error angle were established, and the startup states were classified into six types based on the torque balance relationship to reveal the mechanism of the undesired zero-speed equilibrium. Then, a compensation term proportional to the q-axis control voltage was introduced into the q-axis current prediction equation of the EKF to break the undesired equilibrium and enable normal startup. Simulation results show that at initial error angles of 80°, 160°, and 240°, startup fails in all cases without compensation, whereas successful startup is achieved after compensation is applied. The maximum speed rise time is 0.25 s, and the absolute values of the steady-state speed error and the final position error angle are kept within 4.9 rad/s and 9.2°, respectively. Under variable-speed conditions as well as sudden load application and removal, the system exhibits good robustness, with a maximum absolute steady-state speed error of only 4.36 rad/s. Compared with the existing q-axis current compensation strategy, the proposed strategy achieves a lower steady-state speed error. By integrating state estimation with startup abnormality suppression, the proposed strategy eliminates the need for additional hardware sensors, significantly improves startup reliability under large initial position errors, and provides new insights for the state monitoring of industrial drive systems.

     

/

返回文章
返回